Copper network cabling and connectivity
Panduit network cable
157 Panduit part numbers, with Panduit's own descriptions and datasheets. Every part is quoted by Gross Automation.
Not in our list. Ask us for a quote and include the part number.

IFRH6X04TL-UGCat 6A, 4-pair, 23/1 AWG, F/UTP, CM/CMX/CMR, 600V rated,TealCategory 6A 4-pair F/UTP copper cable shall meet or exceedthe ANSI/TIA-568.2-E Category 6A and ODVA EtherNet/IP™standards. The solid copper conductors shall be 23 AWG withhigh density polyethylene (HDPE) insulation. The copperconductors shall be twisted in pairs. All pairs shall thenbe covered with a foil shield and an industrially rated PVCjacket which shall be oil, sunlight and weld splatter resistantand flame retardant to CMX/CMR for industrial Ethernetapplications.

IURH6X04TL-UGCat 6A, 4-pair, 23/1 AWG, U/UTP, CM/CMX/CMR, 600V rated,TealCategory 6A 4-pair U/UTP copper cable shall meet or exceed the ANSI/TIA-568.2-D Category 6A and ODVA EtherNet/IP standards. The solid copper conductors shall be 23 AWG with HDPE insulation. The copper conductors shall be twisted in pairs and wrapped with a foam polypropylene tape. All pairs shall then be covered with a discontinuous foil shield and an industrially rated PVC jacket which shall be oil and sunlight resistant and flame retardant to CMX/CMR for industrial Ethernet applications.

NUL6C04BU-FECopper Cable, Cat 6, 24 AWG, U/UTP, LSZH-1, BlueThe NetKey™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with HDPE insulation. The conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by a HDPE flame-retardant jacket. The blue, LSZH (IEC 60332-1, EuroClass Dca-s2,d2,a1) cable is supplied 305 meters (1,000 feet) to an easy pay-out carton.

NUL6C04WH-FENetKey™ Copper Cable, Cat 6, 24 AWG, U/UTP, LSZH, Euroclass Dca, WhiteThe NK6™ Cat 6 U/UTP LSZH copper cable is constructed of 24 AWG copper conductors with HDPE insulation. The copper conductors shall be twisted in pairs and separated by a cross divider. All four pairs shall be covered by a flame retardant HDPE (LSZH), White jacket. Packaged 1000 ft./305m in an easy payout carton.

PFO6X04BL-CGZCopper Cable, Category 6A, 4-pair, 23AWG, F/UTP, OSP BlackCategory 6A OSP cable shall meet the ANSI/TIA-568.2-D Category 6Acomponent Standard. The conductors shall be 23 AWG with polyolefininsulation. The cable shall have a gel-filled construction to prevent moisturemigration in underground and wet applications and a wide temperaturerange for extreme weather environments. The copper conductors shall betwisted in pairs, separated by a pair separator, covered with an overall foilshield and a UV and abrasion-resistant polyethylene (PE) jacket.

PFP6C04BL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, BlackCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04BU-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, BlueCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04GR-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, GreenCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04IG-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, Int'l GreyCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04OR-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, OrangeCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04RD-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, RedCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04VL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, VioletCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04WH-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, WhiteCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6C04YL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMP, YellowCategory 6 cable shall exceed the ANSI/TIA-568.2-E Category 6component standards. The conductors shall be 23 AWG constructionwith FEP (CMP) or PE (CMR) insulation. The copper conductors shall betwisted in pairs, separated by a cross divider, and all four pairs shall becovered with an overall foil and a low smoke, flame-retardant (CMP) orflame-retardant (CMR) PVC jacket.

PFP6X04BL-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, BlackCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04BU-UGTX6A™ Copper Cable, Cat 6A, 23 AWG, F/UTP, CMP, BlueThe TX6A™ Cat 6A F/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMP), Blue jacket. Packaged 1000ft/305m on a reel

PFP6X04BU-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, BlueCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04GR-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, GreenCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04IG-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, Int'l GreyCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04OR-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, OrangeCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04RD-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, RedCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04VL-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, VioletCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04WH-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, WhiteCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFP6X04YL-UGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMP, YellowCategory 6A cable shall be constructed of 23 AWG copperconductors with FEP insulation. The copper conductors shall betwisted in pairs and separated by an integrated pair separator. All four pairs shall be surrounded by an overall metallic foil shieldwithin a flame retardant PVC (CMP) jacket. The TX6A ShieldedCopper Cable must be installed as part of a complete TX6AShielded Copper Cabling System to achieve 10GBASE-T certifiedperformance.

PFR6C04BL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, BlackCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04BU-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, BlueCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04GR-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, GreenCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04IG-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, Int'l GreyCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04OR-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, OrangeCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04RD-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, RedCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04VL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, VioletCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04WH-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, WhiteCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6C04YL-UGZCopper Cable, Cat 6, 4 pair, 23 AWG, F/UTP, CMR, YellowCategory 6 cable shall exceed the ANSI/TIA-568.2-D Category 6 componentstandard. The conductors shall be 23 AWG construction with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider,and all four pairs shall be covered with an overall foil and a flame-retardant(CMR) PVC jacket.

PFR6X04BL-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, BlackCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04BU-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, BlueCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04GR-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, GreenCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04IG-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, Int'l GreyCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04OR-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, OrangeCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04RD-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, RedCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04VL-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, VioletCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04WH-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, WhiteCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PFR6X04YL-CGZCopper Cable, Cat 6A, 4-Pair, 23 AWG, F/UTP, CMR, YellowCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductorsshall be twisted in pairs and separated by an integrated pairseparator. All four pairs shall be surrounded by an overall metallicfoil shield within a flame retardant PVC (CMR) jacket. The TX6AShielded Copper Cable must be installed as part of a completeTX6A Shielded Copper Cabling System to achieve 10GBASE-Tcertified performance.

PUL6AHD04BL-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, BlackThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Black, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04BU-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, BlueThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Blue, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04GR-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, GreenThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Green, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04IG-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, GrayThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The International Gray, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04OR-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3,OrangeThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Orange, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04RD-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, RedThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Red, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04VL-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3,VioletThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Violet, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04WH-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3, WhiteThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The White, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUL6AHD04YL-EGCopper Cable, Cat 6A, 23 AWG, U/UTP, LSZH-3,YellowThe TX6A™ Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a flat divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The Yellow, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.

PUO6AS04BL-GTX6A™ Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, Indoor/Outdoor, BlackThe TX6A™ Cat 6A U/UTP Outdoor/Indoor copper cable is constructed of 23 AWG copper conductors with fluoropolymer insulation. The copper conductors shall be twisted in pairs and separated by a cross divider. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a fluoropolymer (CMP), Black jacket. Packaged 1000 ft./305m on a reel.

PUO6AS04WH-GTX6A™ Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, Indoor/Outdoor, WhiteThe TX6A™ Cat 6A U/UTP Outdoor/Indoor copper cable is constructed of 23 AWG copper conductors with fluoropolymer insulation. The copper conductors shall be twisted in pairs and separated by a cross divider. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a fluoropolymer (CMP), White jacket. Packaged 1000 ft./305m on a reel.

PUO6C04BL-CGZCopper Cable, Category 6, 4-pair, 24 AWG, U/UTP, OSP, BlackCategory 6 OSP cable shall meet the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component Standards. The conductors shall be 24 AWG construction with polyolefin insulation. The cable shall havea gel-filled construction to prevent moisture migration in undergroundand wet applications and a wide temperature range for extremeweather environments. The copper conductors shall be twisted inpairs, separated by a pair separator and covered with a UVand abrasion-resistant polyethylene (PE) jacket.

PUO6C2204BL-GZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, OSP, BlackCategory 6 OSP cable shall meet the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component Standards. The conductors shall be22 AWG construction with polyolefin insulation. The cable shall havea gel-filled construction to prevent moisture migration in undergroundand wet applications and a wide temperature range for extremeweather environments. The copper conductors shall be twisted inpairs, separated by a pair separator and covered with a UV- and abrasion-resistant polyethylene (PE) jacket.

PUO6X04BL-CEGTX6A™ Copper Cable, Cat 6a, 23 AWG, U/UTP, Outdoor, Euroclass Fca, BlackThe TX6A™ Cat 6A U/UTP Outdoor copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors shall be twisted in pairs, separated by a cross divider and covered by a UV and abrasion resistant, HDPE flame retardant, Black jacket. Packaged 1000ft/305m on a reel

PUP6AS04BL-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, BlackCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04BU-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, BlueCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04GR-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, GreenCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04IG-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, Int'l GreyCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04OR-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, OrangeCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04RD-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, RedCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04VL-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, VioletCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04WH-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, WhiteCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6AS04YL-GZCopper Cable, Cat 6A , 4-Pair, 23 AWG, U/UTP, CMP, YellowCategory 6A cable shall be constructed of 23 AWG copper conductorswith FEP insulation. The copper conductors shall be twisted in pairs andseparated by a cross-divider. All four pairs shall be surrounded by a nonconductiveAXT barrier tape and a flame retardant PVC (CMP) jacket.

PUP6C04BL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlackThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The black, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04BL-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, BlackThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The black, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04BU-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlueThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The blue, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04BU-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, BlueThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The blue, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04GR-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, GreenThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The green, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04GR-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, GreenThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The green, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04IG-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, International GrayThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The intl.gray, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04IG-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, International GrayThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The intl. gray, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04OR-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, OrangeThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The orange, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04OR-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, OrangeThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The orange, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04RD-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, RedThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The red, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04RD-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, RedThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The red, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04VL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, VioletThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The violet, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04VL-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, VioletThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The violet, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04WH-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, WhiteThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The white, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04WH-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, WhiteThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The white, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04YL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, YellowThe TX6™ Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The yellow, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C04YL-WZCopper Cable, Cat 6, 24 AWG, UTP, CMP, YellowThe TX6™ Cat 6 U/UTP copper cable is constructed of 24 AWG copper conductors with FEP/HDPE insulation. The copper conductors are twisted in pairs. All four pairs are surrounded by a PVC flame-retardant jacket. The yellow, plenum (CMP) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.

PUP6C2204BL-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, BlackCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204BU-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, BlueCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204GR-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, GreenCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204IG-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, Intl. GreyCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204OR-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, OrangeCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204RD-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, RedCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204VL-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, VioletCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6C2204WH-WZCopper Cable, Cat 6A, 4-Pair, 22 AWG, UTP, CMP, WhiteCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 component Standard. The conductors shall be 22 AWG construction with FEP insulation. The copper conductors shall be twisted in pairs, separated by tape divider, and covered by a low smoke, flame-retardant (CMP) PVC jacket. Provides less voltage drop, increased current carrying capacity and reduced heat generation for PoE applications. The cable shall exceed the 100-meter distance for security, ICT, building automation, and IoT applications.

PUP6C2204YL-WZCopper Cable, Extended Reach, Cat 6, 4-Pair, 22 AWG, UTP, CMP, YellowCategory 6 cable shall meet ANSI/TIA-568-2.D Category 6 componentStandard. The conductors shall be 22 AWG construction with FEPinsulation. The copper conductors shall be twisted in pairs, separatedby tape divider, and covered by a low smoke, flame-retardant (CMP)PVC jacket. Provides less voltage drop, increased current carryingcapacity and reduced heat generation for PoE applications. Thecable shall exceed the 100-meter distance for security, ICT, buildingautomation, and IoT applications.

PUP6XHD04BL-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, BlackThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Black jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04BU-GTX6A™ Copper Cable, Cat 6A, 23 AWG, UTP, BlueThe TX6A™ Cat 6A copper cable is constructed of 23 AWG copper conductors with FEP Plenum (CMP) insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and a flame retardant, plenum-rated, blue jacket.

PUP6XHD04GR-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, GreenThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Green jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04IG-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, Int'l GrayThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Gray jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04OR-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, OrangeThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Orange jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04RD-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, RedThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Red jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04VL-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, VioletThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Violet jacket. Packaged 1000 ft./305m on a reel.

PUP6XHD04WH-GTX6A™ Copper Cable, Cat 6A, 23 AWG, UTP, WhiteThe TX6A™ Cat 6A copper cable is constructed of 23 AWG copper conductors with FEP Plenum (CMP) insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and a flame retardant, plenum-rated, white jacket.

PUP6XHD04YL-GTX6A™ Vari-MaTriX Copper Cable, Cat 6A, 23 AWG, U/UTP, CMP, YellowThe TX6A™ Cat 6A U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP insulation. The copper conductors shall be twisted in pairs. All four pairs shall be surrounded by a metallic alien crosstalk barrier tape and covered by a flame retardant PVC (CMP), Yellow jacket. Packaged 1000 ft./305m on a reel.

PUP6004BL-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlackThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) black jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004BL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlackThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, black jacket.

PUP6004BL-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, BlackCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004BU-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlueThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) blue jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004BU-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, BlueThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, blue jacket.

PUP6004BU-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, BlueCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004GR-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, GreenThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) green jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004GR-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, GreenThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, green jacket.

PUP6004GR-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, GreenCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004IG-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, International GrayThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) intl. gray jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004IG-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, International GrayThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, intl.gray jacket.

PUP6004IG-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, Int'l GreyCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004OR-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, OrangeThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) orange jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004OR-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, OrangeThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, orange jacket.

PUP6004OR-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, OrangeCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004RD-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, RedThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) red jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004RD-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, RedThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, red jacket.

PUP6004RD-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, RedCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004VL-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, VioletThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) violet jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004VL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, VioletThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, violet jacket.

PUP6004VL-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, VioletCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004WH-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, WhiteThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) white jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004WH-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, WhiteThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, white jacket.

PUP6004WH-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, WhiteCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6004YL-ULPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, YellowThe TX6000™ Enhanced Category 6 U/UTP Copper Cable is constructed of 23 AWG conductors with FEP/polyolefin insulation. The copper conductors are twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant (CMP) yellow jacket supplied 305m (1000 ft.) in a reel in a carton. The cable has been tested as part of the TX6000™ Enhanced Copper Cabling System and exceeds the ANSI/TIA-568.2-D and ISO 11801 Class E electrical channel requirements with guaranteed headroom.

PUP6004YL-WLPZCopper Cable, Cat 6, 23 AWG, UTP, CMP, YellowThe TX6000™ Cat 6 UTP copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin (CMP) insulation. The copper conductors shall be twisted in pairs, separated by a cross-divider and covered by a low smoke, flame-retardant, plenum-rated, yellow jacket.

PUP6004YL-WZCopper Cable, Cat 6, 4-Pair, 23 AWG, U/UTP, CMP, YellowCategory 6 cable shall exceed the ANSI/TIA-568.2-D and IEC61156-5 Category 6 component standards. The conductorsshall be 23 AWG construction with FEPor polyolefin insulation. The copper conductors shall be twisted in pairs, separated bya cross-divider and covered by a low smoke, flame-retardant(CMP) jacket.

PUP6504GR-UYTX6500™ Copper Cable, Cat 6, 23 AWG, U/UTP, CMP-LP, GreenThe TX6500™ Cat 6 U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin insulation. The copper conductors shall be twisted in pairs and separated by a cross divider. All four pairs shall be covered by a flame retardant PVC (CMP), Green jacket. Packaged 1000 ft./305m on a reel in a box.

PUP6504VL-UYTX6500™ Copper Cable, Cat 6, 23 AWG, U/UTP, CMP-LP, VioletThe TX6500™ Cat 6 U/UTP Plenum copper cable is constructed of 23 AWG copper conductors with FEP/polyolefin insulation. The copper conductors shall be twisted in pairs and separated by a cross divider. All four pairs shall be covered by a flame retardant PVC (CMP), Violet jacket. Packaged 1000 ft./305m on a reel in a box.

PUR6AHD04BL-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, BlackCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04BU-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, BlueCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04GR-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, GreenCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04IG-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, Int'l GreyCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04OR-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, OrangeCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04RD-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, RedCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04VL-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, VioletCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04WH-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, WhiteCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AHD04YL-GCopper Cable, Cat 6A, 4-Pair, 23 AWG, UTP, CMR, YellowCategory 6A/Class EA cable shall be constructed of 23 AWG copper conductors with Foam PE and HDPE insulation. The copper conductors shall be twisted in pairs and separated by a tape-style divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape and a flame retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity.

PUR6AS04BL-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, BlackCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04BU-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, BlueCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04GR-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, GreenCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04IG-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, Int'l GreyCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04OR-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, OrangeCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04RD-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, RedCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04VL-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, VioletCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04WH-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, WhiteCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PUR6AS04YL-ZCopper Cable, Cat 6A, 4-Pair, 23 AWG, U/UTP, CMR, YellowCategory 6A cable shall be constructed of 23 AWG copperconductors with polyolefin insulation. The copper conductors shallbe twisted in pairs and separated by a cross-divider. All four pairsshall be surrounded by an AXT barrier tape and a flame retardant(CMR) jacket. The AXT barrier tape shall minimize the cablediameter and suppress the effects of alien crosstalk while retainingU/UTP electromagnetic interference immunity.

PURCA6X04BU-CGCopper Cable, Cat 6A, 2x4-Pair, 23 AWG, Armored, U/UTP, CMR, BlueCategory 6A cable shall meet the ANSI/TIA-568.2-D Category 6A and IEC 61156-5component standards. The conductors shall be 23 AWG insulated with foam PE andHDPE. The copper conductors shall be twisted in pairs, separated by a cross dividerand covered by a flame retardant (CMR) PVC jacket in an aluminum interlock armorwith an overall flame retardant (CMR) PVC jacket.

PURCA26X04BU-CGCopper Cable, Cat 6A, 4-Pair, 23 AWG, Armored, U/UTP, CMR, BlueTwo Category 6A cables shall meet the ANSI/TIA-568.2-DCategory 6A and IEC 61156-5 component standards. Theconductors shall be 23 AWG insulated with foamed PE andHDPE. The copper conductors shall be twisted in pairs,separated by a cross divider with an overall AXT barrier tapeand covered by a flame retardant PVC (CMR) jacket in analuminum interlock armor with an overall flame retardant PVC(CMR) jacket.

SP-SFCS1IG-CEGSPE Shielded Copper Cable, S/FTP, CM/CMR, 18/7 AWGThe SPE Shielded Copper Cable has 18/7 AWG stranded tinned copper conductors with foamed polyethylene (PE) insulation. The conductors are twisted in a pair and include two fillers. The pair is surrounded by an aluminum/polyester foil shield, a tinned copper braid shield, and includes a 24/7 AWG stranded tinned copper ground wire. The PVC jacket is oil, UV, and abrasion resistant for enhanced chemical resistance, mechanical performance, and flame retardant (CM/CMR) for industrial applications.

VS-AVT-CABLE-02VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 2 ft

VS-AVT-CABLE-04VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 4 ft

VS-AVT-CABLE-08VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 8 ft

VS-AVT-CABLE-16VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 16 ft

VS-AVT-CABLE-20VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 20 ft

VS-AVT-CABLE-30VeriSafe™ 600V Replacement CableVeriSafe™ 600V Replacement Cable, 30 ft
Buy Panduit from Gross Automation
Gross Automation has distributed industrial automation and electrical control products for more than 30 years. Send part numbers and quantities and we will quote them: request a quote or call +1 (262) 252-1600. Building a control panel? Our UL 508A panel shop is at grossmfg.com.